# Copyright 1999-2021 Gentoo Authors # Distributed under the terms of the GNU General Public License v2 EAPI=5 inherit eutils linux-info flag-o-matic systemd udev tmpfiles DESCRIPTION="APC UPS daemon with integrated tcp/ip remote shutdown" HOMEPAGE="http://www.apcupsd.org/" SRC_URI="mirror://sourceforge/apcupsd/${P}.tar.gz" LICENSE="GPL-2" SLOT="0" KEYWORDS="amd64 ~arm ppc x86" IUSE="snmp +usb cgi nls gnome kernel_linux" DEPEND=" >=sys-apps/util-linux-2.23[tty-helpers(-)] cgi? ( >=media-libs/gd-1.8.4 ) nls? ( sys-devel/gettext ) snmp? ( >=net-analyzer/net-snmp-5.7.2 ) gnome? ( >=x11-libs/gtk+-2.4.0:2 dev-libs/glib:2 >=gnome-base/gconf-2.0 )" RDEPEND="${DEPEND} sys-apps/openrc virtual/mailx" CONFIG_CHECK="~USB_HIDDEV ~HIDRAW" ERROR_USB_HIDDEV="CONFIG_USB_HIDDEV: needed to access USB-attached UPSes" ERROR_HIDRAW="CONFIG_HIDRAW: needed to access USB-attached UPSes" pkg_setup() { if use kernel_linux && use usb && linux_config_exists; then check_extra_config fi } src_prepare() { epatch "${FILESDIR}/${PN}-3.14.9-aliasing.patch" } src_configure() { local myconf use cgi && myconf="${myconf} --enable-cgi --with-cgi-bin=/usr/libexec/${PN}/cgi-bin" if use usb; then myconf="${myconf} --with-upstype=usb --with-upscable=usb --enable-usb --with-dev= " else myconf="${myconf} --with-upstype=apcsmart --with-upscable=smart --disable-usb" fi # We force the DISTNAME to gentoo so it will use gentoo's layout also # when installed on non-linux systems. econf \ --sbindir=/sbin \ --sysconfdir=/etc/apcupsd \ --with-pwrfail-dir=/etc/apcupsd \ --with-lock-dir=/run/apcupsd \ --with-pid-dir=/run/apcupsd \ --with-log-dir=/var/log \ --with-nis-port=3551 \ --enable-net --enable-pcnet \ --with-distname=gentoo \ $(use_enable snmp net-snmp) \ $(use_enable gnome gapcmon) \ ${myconf} \ APCUPSD_MAIL=/bin/mail } src_compile() { # Workaround for bug #280674; upstream should really just provide # the text files in the distribution, but I wouldn't count on them # doing that anytime soon. MANPAGER=$(type -p cat) \ emake } src_install() { emake DESTDIR="${D}" install rm -f "${D}"/etc/init.d/halt insinto /etc/apcupsd newins examples/safe.apccontrol safe.apccontrol doins "${FILESDIR}"/apcupsd.conf dodoc ChangeLog* ReleaseNotes doman doc/*.8 doc/*.5 dohtml -r doc/manual/* rm "${D}"/etc/init.d/apcupsd newinitd "${FILESDIR}/${PN}.init.4" "${PN}" newinitd "${FILESDIR}/${PN}.powerfail.init" "${PN}".powerfail systemd_dounit "${FILESDIR}"/${PN}.service dotmpfiles "${FILESDIR}"/${PN}-tmpfiles.conf # remove hal settings, we don't really want to have it around still. rm -r "${D}"/usr/share/hal # replace it with our udev rules if we're in Linux if use kernel_linux; then udev_newrules "${FILESDIR}"/apcupsd-udev.rules 60-${PN}.rules fi } pkg_postinst() { tmpfiles_process ${PN}-tmpfiles.conf if use cgi; then elog "The cgi-bin directory for ${PN} is /usr/libexec/${PN}/cgi-bin." elog "Set up your ScriptAlias or symbolic links accordingly." fi elog "" elog "Since version 3.14.0 you can use multiple apcupsd instances to" elog "control more than one UPS in a single box with openRC." elog "To do this, create a link between /etc/init.d/apcupsd to a new" elog "/etc/init.d/apcupsd.something, and it will then load the" elog "configuration file at /etc/apcupsd/something.conf." elog "" elog 'If you want apcupsd to power off your UPS when it' elog 'shuts down your system in a power failure, you must' elog 'add apcupsd.powerfail to your shutdown runlevel:' elog '' elog ' \e[01m rc-update add apcupsd.powerfail shutdown \e[0m' elog '' if use kernel_linux; then elog "Starting from version 3.14.9-r1, ${PN} installs udev rules" elog "for persistent device naming. If you have multiple UPS" elog "connected to the machine, you can point them to the devices" elog "in /dev/apcups/by-id directory." fi }